NET832BM

NET832BM is a wired/wireless intrusion detection control unit with 8 inputs on board, expandable up to 16 with split mode. It allows high quality intrusion detection systems for residential and commercial environments. It’s provided with the BOXM housing wich allows the installation of a 12V/18Ah battery.

The control unit can manages 32 total inputs thanks to the optional RIVER concentrators. The installation,  the programming and the management are very simple thanks to the interface with the NET5GSM optional module wich allows the comminucation via GSM to enable the remote interrogation and the remote control.

NET832BM  allows also the communication with the e-Connect interface thanks to the ELAN832 optional module. 

  • Inputs

    • 8 inputs expandable up to 16 split mode inputs, 16 additional inputs with optional concentrators up to 32 total inputs

    Outputs

    • 8 electronic programmable outputs for ETRREL optional module connection

    Users

    • 64 user codes management

    Areas/sectors

    • One area parzializable  up to 4 sectors

    Control devices

    • 4 control devices ANIMA, TATTILO, NIRVA, MIDAS
    • 4 IZENITH or i8 proximity readers

    User’s interface

    • Programming from control device
    • Wired programming from PC with compatible broswer or wired/wireless with WINASSIST

    Serial line

    • RS232 serial line for PC programming (CP8/SER2 cable required)
    • 2 power supply boxes mod. C10RS or AL3RS management via RS485 serial line
    • RS485 serial line for compatible devices connection ( control devices, detectors, etc.)

    Clock

    • Internal clock with back up battery

    Wireless module

    • Optional RIVERRF wireless interface

    Memory events

    • Last 300 events

    Connectors

    • Minidin connector for programming, firmware update and management from PC
    • Connector for optional ETRREL module
    • Connector for optional NET5GSM module

    Phone dialler

    • Phone line connection for digital transmissions with Fast Format, ADEMCO IDCONTACT protocol

    Voice synthesis

    • Phone transmissions with optional SKVOICE8 module
    • Simplify remote interrogation with tones answer even without SKVOICE8
    • Message management and recording, from broswer too
    • 8 phone numbers for phone transmissions and 2 phone numbers for digital transmissions
    • Remote assistance via integrated 300bps modem

    GSM

    • Optional NET5GSM module and remote interrogation, remote control via SMS

    LAN

    • Optional ELAN832 module connectable via CP8/SER2 cable (not provided)

    Functions

    • Weekly/yearly programmer with 24 schedules, holidays management, DST/standard time automatic switching
    • System fast test function
    • Weekly programmer with 8 programs for outputs arm/disarm
    • User codes masking for broswer connection
    • System lock function for maintenance
    • Din Don functions, aggression, timed input assignable to inputs

    Housing

    • Metal

    Battery

    • 12V/18Ah

    Protection class

    • IP3X

    Operating temperature

    • -10/+40 °C, 93% U.R.

    Environmental class

    • II according to EN50130-5

    Dimensions/weight

    • Standard housing: W 225 x H 275 x D 110 mm.
    • BOXM housing: W 325 x H 304 x D 133 mm.
    • 2,120 Kg without power supply support bracket and standard housing

    Power consumption

    • 0,2 A

    Power supply

    • Switching power supply AL3SWJST 14,5V/3A to place into the housing (not provided)

    Power supply

    • 230Vac

    Performance level

    • I°, II° against removal (CEI 79-2).

    Standards

    • Compliant with EN50131-1, EN50131-3 grade 2, EN50131-6

    Parts supplied

    • 17 inputs balance resistors 1500 Ohm
    • 8 resistors 2200 Ohm
    • 2 resistors 680 Ohm for serial line
    • Power supply fixing bracket and screws
    • Rubber cable routing
    • Tamper microswitch against housing opening
    • Tamper microswitch against removal with plate and fixing screws
    • Techincal manual and user manual
    • Socket
    • 2 biadhesive stripes for back up battery
    • CD with browser
  • CENTRALE NET832

    284.56 KB

    • NET832

      Brochure della centrale antintrusione a 32 ingressi NET832

  • Software Configuration

    Datasheet

    • Foglio Tecnico
      Model
      19/01/2015
       
    • Data Sheet
      Model
      20/01/2015
       

    Product Description

    • Descrizione Capitolato
      Model
      13/01/2014
       
    • Product Description
      Model
      13/01/2014
       

    User Manual

    Technical Manual

    • Manuale Tecnico
      Model
      13/01/2014
       
    • Technical Manual
      Model
      13/01/2014
       

    Programming Manual

    • Manuale di Programmazione
      Model
      13/01/2014
       

    CE - DoP

    • CE - DoP
      Model
      02/05/2017
       
    • CE - DoP
      Model
      02/05/2017
       

    Notified Body

    • IMQ
      Model
      13/01/2014
       

    Report Test

    • Test Report
      Model
      13/01/2014
       

    Programming Manual reduced

    • Manuale di programmazione ridotto
      Model
      13/01/2014
       
    • Abridged Programming Manual
      Model
      13/01/2014
       
  • User Manual

    Technical Manual

    • Manuale Tecnico
      Model
      13/01/2014
       
    • Manuale Tecnico
      Model
      13/01/2014
       
    • Technical Manual
      Model
      13/01/2014
       
    • Manuale Tecnico
      Model
      13/01/2014
       
    • Technical Manual
      Model
      13/01/2014
       

    Programming Manual

    • Manuale di Programmazione
      Model
      13/01/2014
       
    • Manuale di Programmazione
      Model
      13/01/2014
       
    • Manuale di Programmazione
      Model
      13/01/2014
       
    • Development manual
      Model
      13/01/2014
       
    • Manuale di Programmazione
      Model
      13/01/2014
       

    Software

    • Software v.4.1.1
      Model
      13/01/2014
       
    • Software v.3.0.2
      Model
      13/01/2014
       
    • Software v.3.0
      Model
      13/01/2014
       
    • Software v.2.0.2
      Model
      13/01/2014
       
    • Software v2.0.2
      Model
      13/01/2014
       
    • Software v.2.0.2
      Model
      13/01/2014
       
    • Software v.1.0
      Model
      13/01/2014
       

    Firmware

    • Firmware v.4.4
      Model
      13/01/2014
       
    • Firmware v.4.5
      Model
      13/10/2014
       
    • Firmware v.3.4
      Model
      13/01/2014
       
    • Firmware v.3.2
      Model
      13/01/2014
       
    • Firmware v.2.3
      Model
      13/01/2014
       
    • Firmware v.2.3
      Model
      13/01/2014
       
    • Firmware v.2.3
      Model
      13/01/2014
       
    • Firmware v.1.0
      Model
      13/01/2014
       

    Programming Manual reduced

    • Manuale di programmazione ridotto
      Model
      13/01/2014
       
    • CCNET0100400
      Centrale NET832 IMQ in contenitore BOXM 8ing. esp. a 16 split, + 16ing. su Bus RS485 
    • CCNET0100401
      NET832 IMQ control unit in BOXM housing 8/16 inputs, up to 32 on RS485 bus - ENGLISH VERSION

Active Products