Analogic interface modules

Modules equipped with inputs and outputs and other interface to be used on field to receive the signals from external devices and to interact with them and the control unit.
MD1IO

MD1IO

MD1IO is a FYRA 1IN/1OUT module for analogue-addressable loops. It features one balanced / non-balanced input for alarm and fault (line open and line short circuit) used to connect on the loop 1 detector, or other conventional device, equipped with one N.O. relay contacts and one output to control acoustic/optical-acoustic devices or other devices.
MD4IO

MD4IO

MD4IO is a 4IN/4OUT module for FYRA analogue-addressable loops. It features balanced / non-balanced inputs for alarm and fault (line open and line short circuit) used to connect on the loop 4 detectors or other conventional device equipped with N.O. relay contacts and 4 C-NO-NC bistable relay outputs (2A load at DC30V) supporting the connection of devices indicated by the current law in case of non-supervised outputs only (e.g. devices for technological events).

MD1P

MD1P

MD1P is a module for FYRA loops designed for the simple control of 1 door. It is equipped with 1 balanced input and 1 output associated between them to receive signals from devices or detectors to control 1 door or 1 fire door and to activate their closure with its output relay. The module also features 1 independent balanced / non-balanced input for alarm and fault (open line and line short circuit) used to connect on the loop 1 detector or other conventional device equipped with N.O. relay contacts.

MD2P

MD2P

MD2P is a module for the complete control of 2 doors for FYRA loops. It is equipped with 4 balanced inputs and 2 outputs associated between them to receive signals from devices or detectors to control 2 doors or 2 fire doors and to activate their closure with its output relay. Each output relay manages 2 inputs that control door status: one input controls door open state, the other input controls door closed status.


1IASBOX

1IASBOX

AS analogue fire detection module with 1 input

EV-AV

EV-AV

Evolution loop optical-acoustic module


VCT-03CPR

VCT-03CPR

Red cover for VCT03NT-03NSTAS

VCT03CPW

VCT03CPW

Analogue fire detection module white cover for AS-ABS and EV-ABS


NAMASG

NAMASG

AS analogue fire detection module for 4-20mA gas detectors

HLPL

Interface for connection of HLPOWER to FYRA loop

MDCONV

MDCONV

[NB763-I] MDCONV is a module for FYRA loops that allows to integrate conventional detectors and alarm call points for the manual triggering of fire alarms on analogue-addressable loops. The module is equipped with an integrated isolator protecting the line in case of short circuits,

Active Products